Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38587219

RESUMEN

AIM: To conduct a bibliometric network analysis to explore the research landscape of immediate implant placement (IIP) and provide insights into its trends and contributors. MATERIALS AND METHODS: The Scopus database was utilized as the bibliographic source, and a search strategy was implemented to identify relevant research articles. Various bibliometric parameters were extracted, including publication year, journal, authors, citations, and funding. The analysis involved examining authorship patterns, international collaborations, level of evidence, Altmetric data, and funding analysis. RESULTS: We identified a steady annual growth rate of 6.49% in IIP research. The top three countries contributing to research output were the USA, Italy, and China. Prolific authors were identified based on publication and citation metrics. International collaborations among different countries were observed. The level of evidence analysis revealed that over 30% of the articles fell into higher levels of evidence (levels 1 and 2). Altmetric data analysis indicated no significant correlations between citation counts and Altmetric Attention Score (AAS), and conversely a significant association with Mendeley readers count. Funding and open access did not significantly impact the bibliometric indices of the papers. CONCLUSIONS: The focus of research on IIP has been evolving as indicated by an exponential growth rate in this study. Only approximately 16% of the articles fit into level 1 evidence, therefore, emphasizing on higher quality level research study shortage in this field. Modern indices can be used as new bibliometric indicators as they also cover social media and online attention scores.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37471156

RESUMEN

Successful rehabilitation of severely atrophic, short-span edentulous ridges in esthetic regions can seldom be done without some form of vertical ridge augmentation (VRA). The best available evidence shows that guided bone regeneration procedures may present a very predictable option with reduced potential for complications compared to alternative options. The present case series presents a novel technique to achieve predictable VRA with a low complication rate using tenting screws and cross-linked resorbable membranes. A total of 10 patients (5 men, 5 women) with severe vertical defects in the esthetic zone participated in this study. Following a mean healing time of 9.3 months, the mean defect resolution was 80%, with a mean vertical bone gain of 6.2 ± 1.61 mm. Only one case presented with reduced defect resolution (50%); however, the bone gain for this case was 6 mm.


Asunto(s)
Aumento de la Cresta Alveolar , Implantación Dental Endoósea , Masculino , Humanos , Femenino , Implantación Dental Endoósea/métodos , Aumento de la Cresta Alveolar/métodos , Estética Dental , Regeneración Ósea , Trasplante Óseo/métodos , Colágeno , Membranas Artificiales
3.
J Esthet Restor Dent ; 36(1): 124-134, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37830507

RESUMEN

INTRODUCTION: Regeneration of the missing papilla adjacent to single implants in the esthetic zone has always been challenging, despite advances in vertical hard and soft tissue regeneration. Orthodontic tooth extrusion has been shown to effectively gain alveolar bone and gingival tissue. This retrospective study evaluated the effectiveness of orthodontic tooth extrusion on regenerating missing papilla between existing maxillary anterior single implant and its adjacent tooth. METHODS: Patients who underwent orthodontic tooth extrusion to regenerate missing papilla adjacent to a single implant in the esthetic zone were included in this study. The gingival phenotype, orthodontic extrusion movement, proximal bone level, dento-implant papilla level, facial gingival level, mucogingival junction level, and keratinized tissue width, of the extruded tooth were recorded at pre-orthodontic extrusion (T0 ), post-orthodontic extrusion and retention (T1 ), and latest follow-up (T2 ). RESULTS: A total of 17 maxillary single tooth had orthodontic tooth extrusion to regenerate missing papilla adjacent to 14 maxillary anterior single implants in 14 patients. After a mean follow-up time of 48.4 months, implant success rate was 100% (14/14), with none of the orthodontically extruded teeth being extracted. After a mean extrusion and retention period of 14.3 months, a mean orthodontic extrusion movement of 4.62 ± 0.78 mm was noted with a mean proximal bone level gain of 3.54 ± 0.61 mm (77.0% efficacy), dento-implant papilla level gain of 3.98 ± 0.81 mm (86.8% efficacy), and facial gingival tissue gain of 4.27 mm ± 0.55 mm (93.4% efficacy). A mean keratinized tissue width gain of 4.17 ± 0.49 mm with minimal mean mucogingival junction level change of 0.10 ± 0.30 mm were observed. The efficacy of orthodontic eruption movement on dento-implant papilla gain was less in the thin (80.5%) phenotype group when compared with that in the thick (91.5%) phenotype group. CONCLUSIONS: Within the confines of this study, orthodontic extrusion is an effective, noninvasive method in regenerating mid-term stable proximal bone and papilla adjacent to maxillary anterior single implants. CLINICAL SIGNIFICANCE: This retrospective study presents a mid-term result on orthodontic extrusion as a mean to regenerate dento-implant papilla defect. The extended retention period following orthodontic extrusion showed stable and efficacious proximal bone and papilla gain.


Asunto(s)
Implantes Dentales de Diente Único , Extrusión Ortodóncica , Humanos , Extrusión Ortodóncica/métodos , Estudios Retrospectivos , Incisivo , Encía , Maxilar/cirugía , Resultado del Tratamiento , Estética Dental , Implantación Dental Endoósea
4.
Int J Oral Maxillofac Implants ; 38(6): 1145-1150, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38085745

RESUMEN

PURPOSE: To assess site-related features of peri-implantitis occurring adjacent to teeth and its association with the proximal periodontal bone level. MATERIALS AND METHODS: Periapical radiographs were collected from partially edentulous patients exhibiting peri-implantitis adjacent to teeth. The following variables were quantified: intrabony defect width (DW), implant marginal bone loss (MBLi), tooth marginal bone loss (MBLt), implant-tooth distance (ITd), intrabony defect angulation (DA), adjacent periodontal bone peak height (ABPh), and implant-tooth angulation (ITa). A correlation matrix using the Spearman correlation coefficient was created to explore the dependence of these variables. Univariate linear regression analysis was carried out by means of generalized estimating equations (GEE), using MBLt as dependent variable. RESULTS: Overall, 61 patients and 84 implants were included in this study, consisting of a total of 105 implant sites facing adjacent teeth. This resulted in 515 linear and 194 angular measurements. A total of 11 different statistically significant associations were demonstrated between the different variables analyzed. Moreover, the univariate regression analysis revealed significant positive associations between MBLt and MBLi (P = .013) and between MBLt and periodontitis (PD) (P = .014). These associations were confirmed in the multivariate model. CONCLUSIONS: Teeth adjacent to untreated peri-implantitis lesions are associated with proximal loss of periodontal support. This finding is more remarkable in scenarios that display short implant-tooth distance.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Periimplantitis , Periodontitis , Pérdida de Diente , Diente , Humanos , Periimplantitis/diagnóstico por imagen , Periimplantitis/etiología , Periimplantitis/patología , Estudios Transversales , Implantes Dentales/efectos adversos , Diente/patología , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/etiología
5.
J Oral Implantol ; 49(5): 495-500, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37776256

RESUMEN

The socket shield technique and subepithelial connective tissue graft following immediate implant placement with provisionalization had been advocated for peri-implant facial contour and gingival architecture preservation. This case report used three-dimensional volumetric analysis to longitudinally assess the peri-implant facial contour change before and after these procedures. The results demonstrated comparable and acceptable preservation of peri-implant facial contour between the two procedures after 2 years of function.


Asunto(s)
Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Humanos , Carga Inmediata del Implante Dental/métodos , Alveolo Dental/cirugía , Tejido Conectivo/trasplante , Encía/trasplante , Estética Dental
6.
J Prosthet Dent ; 130(5): 741.e1-741.e9, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37689572

RESUMEN

STATEMENT OF PROBLEM: Screw access channels that emerge on the facial aspect of anterior screw-retained implant crowns can compromise esthetics. Recently, angled screw channels (ASCs) have been developed that can alter screw access channel angulations to improve esthetics. While ASCs can be used on narrow-diameter implants, information is limited on the loss of abutment screw torque on narrow-diameter implants with ASCs. PURPOSE: The purpose of this in vitro study was to compare the loss of abutment screw torque after thermocycling and the cyclic loading of ASCs from 3 different companies connected to narrow-diameter implants. MATERIAL AND METHODS: A total of 40 narrow-diameter implants (NobelReplace Conical Connection 3.5×11.5 mm) were mounted individually in acrylic resin blocks and divided equally into 4 groups. The first group, NB-0 (Control), consisted of screw-retained zirconia crowns fabricated on ASCs at 0-degree angulation (n=10). The other 3 groups consisted of a total of 30 screw-retained zirconia crowns fabricated on ASCs at 20-degree angulation: NB-20 (Angulated Screw Channel Solutions), ATL-20 (Atlantis Custom Base Solution with angulated screw access), and DA-20 (Dynamic TiBase). Each crown was secured on the mounted implant with its corresponding titanium base insert and screw and then tightened to the manufacturer's recommended torque with a digital torque gauge. The initial reverse torque value (RTVI) was obtained and recorded at baseline. Subsequently, a new set of screws were tightened to recommended values, and each specimen underwent thermocycling and then cyclic loading at 0 to 100 N at 10 Hz for 1 million cycles to simulate 1year of functional loading. After cyclic loading, the final reverse torque values (RTVF) were recorded and compared with the RTVI to evaluate the percentage torque loss (PTLF). Statistical analysis was performed using the Kruskal-Wallis analysis, Rank base analysis of covariance (ANCOVA), and the Tukey HSD post hoc comparisons (α=.05). RESULTS: Significant differences were found for the PTLF among all groups after cyclic loading (P<.001). The PTLF in ATL-20 (51.4%) was significantly higher than in NB-0 (22.2%) (P<.001) and NB-20 (29.2%) (P=.010). No significant difference was found in the PTLF among other groups (P>.05). CONCLUSIONS: The abutment screw torque loss after cyclic loading of the ASCs on narrow diameter implants among the 4 groups did not perform comparably. The largest percentage torque loss was recorded for the ATL-20 group. The NB-20 group demonstrated the lowest percentage torque loss. DA-20 showed percentage torque loss less than ATL-20; however, its RTVF was the lowest.


Asunto(s)
Implantes Dentales , Torque , Análisis del Estrés Dental/métodos , Diseño de Implante Dental-Pilar , Pilares Dentales , Estética Dental , Coronas , Tornillos Óseos
7.
Artículo en Inglés | MEDLINE | ID: mdl-37552192

RESUMEN

This retrospective study investigates the efficacy of the socket shield (SS) in preserving inter-implant papilla and bone in anterior adjacent implant sites. Clinical and radiographic records of 23 patients were evaluated. A total of 31 implants were placed immediately into extraction sockets with SS, resulting in 26 inter-implant sites, and 7 implants were placed without SS. After a mean follow-up of 41.5 months (range: 12 to 124 months), 30/31 (96.8%) implants with SS and 7/7 (100%) implants without SS were clinically successful. The mean changes in inter-implant papilla and bone heights were -0.40 mm and -0.46 mm, respectively. The effects of implant placement timing and the socket shield number, shape, and crestal level on inter-implant tissue height changes were found to be insignificant (P > .05). Supracrestal shield level (31.6% vs 16.6% in equicrestal), U-shape shield (41.2% vs 7.1% in C-shape), and shield-to-implant contact (40.0% vs 12.5% in no contact) were associated with increased occurrence of exposures. The application of SS in adjacent anterior implant situations is a viable treatment option for maintaining inter-implant papilla.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Estudios Retrospectivos , Alveolo Dental/cirugía , Resultado del Tratamiento , Carga Inmediata del Implante Dental/métodos , Extracción Dental/métodos , Estética Dental
8.
Compend Contin Educ Dent ; 44(7): 392-401, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37450677

RESUMEN

An intact extraction socket has been considered a prerequisite for an immediate implant placement and provisionalization (IIPP) procedure. Recent studies, however, have shown successful outcomes when IIPP was performed in sockets with a facial bone wall defect. This retrospective study evaluated the facial implant mucosal stability following IIPP in extraction sockets with a facial bone wall defect in the esthetic zone. The study included 16 cases in 16 patients who received maxillary anterior single IIPP with contour bone graft (C-BG) and contour connective tissue graft (C-CTG) in compromised extraction sockets (V- or U-shaped defect). After a mean follow-up of 6 years, the implant success rate was 100% (16/16). Minimal and non-statistically significant changes were noted in the facial implant mucosal and marginal bone level. Statistically significant changes were observed in facial implant mucosal thickness gain (2.5 mm [1.8 mm to 3.5 mm]) and midfacial bone sounding reduction (6 mm). Within the confines of this study, IIPP with simultaneous C-BG and C-CTG in fresh extraction sockets exhibiting a V- or U-shaped facial bone wall defect can lead to long-term successful outcomes in terms of mucosal stability, contour bone gain, and marginal bone level stability.


Asunto(s)
Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Humanos , Estudios Retrospectivos , Alveolo Dental/cirugía , Resultado del Tratamiento , Carga Inmediata del Implante Dental/métodos , Estudios Prospectivos , Estética Dental , Maxilar/cirugía , Extracción Dental
9.
Compend Contin Educ Dent ; 44(7): 385-389; quiz 390, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37450676

RESUMEN

Implant rehabilitation in the esthetic zone is often challenged by vertical bone defects and soft-tissue deformities. This article describes a combined hard- and soft-tissue restorative approach that involves staged guided bone regeneration, implant placement, and two soft-tissue augmentation procedures to achieve optimal esthetic outcomes at multiple implant sites in the anterior zone. The staged bone augmentation procedure, performed with a mixture of autogenous and xenogeneic bone graft and a nonresorbable membrane, allowed for the placement of three implants in ideal positions after 9 months. Further soft-tissue augmentation involved the use of multiple connective tissue grafts (CTGs) stabilized on the occlusal aspect of the implants and between the implants to enhance peri-implant papillae (ie, the "iceberg" CTG approach). Then, a second soft-tissue grafting procedure was executed to reposition the mucogingival junction and re-establish an adequate amount of keratinized mucosa at the implant sites. The article highlights the importance of performing both hard- and soft-tissue augmentation for implant therapy in the esthetic zone.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales de Diente Único , Implantes Dentales , Maxilar/cirugía , Estética Dental , Implantación Dental Endoósea/métodos , Encía/cirugía , Aumento de la Cresta Alveolar/métodos , Resultado del Tratamiento
10.
Clin Implant Dent Relat Res ; 25(5): 789-794, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37232408

RESUMEN

OBJECTIVE: The purpose of this cone beam computed tomography (CBCT) study was to determine the frequency percentage of screw-retained crown using angulated screw channel (ASC) abutment for single immediate implant placement and provisionalization (IIPP) in the esthetic zone. METHODS: The CBCT images of 200 patients without disease and without metal restorations in maxillary anterior teeth were evaluated. The mid-sagittal-sectional CBCT images of maxillary anterior teeth (#6-#11) were created in an implant planning software, screen-captured, and transferred to a presentation program. Template of tapered implants with diameter of 3.5 mm (for central and lateral incisors) and 4.3 mm (for central incisors and canines) and lengths of 13, 15, and 18 mm were applied to the sagittal images to identify the IIPP cases. To qualify for IIPP, the implant must engage >35% bone with at least 1 mm of surrounding bone and no perforations. The IIPP cases were further divided into straight screw channel (IIPPSSC) abutment or 25-degree angulated screw channel abutment (IIPPASC), based upon its restorability. The frequency percentages of possible IIPP, IIPPSSC, and IIPPASC were reported and compared among all maxillary anterior teeth. RESULTS: A total of 1200 maxillary anterior teeth sagittal images from 200 patients (88 male and 112 female) with a mean age of 51.3 years (range 20-83 years) were evaluated in this study. The overall frequency percentages of IIPP, IIPPSSC, and IIPPASC possibility were 84% (74%-92%), 14% (10%-24%), and 75% (66%-87%), respectively. CONCLUSION: Within the limitations of this CBCT study, 90% of single IIPP in the esthetic zone can be restored with screw-retained crown when utilizing ASC. In addition, the possibility of using a screw-retained restoration following IIPP increases about five times with ASC abutment compared to the SSC abutment.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estética Dental , Coronas , Tomografía Computarizada de Haz Cónico/métodos , Tornillos Óseos , Proceso Alveolar , Maxilar/diagnóstico por imagen , Maxilar/cirugía
11.
Artículo en Inglés | MEDLINE | ID: mdl-37232678

RESUMEN

Maintaining facial soft tissue contour and inter-implant papilla are challenging for implants in the esthetic zone. To counteract the inevitable hard and soft tissue changes after tooth extraction, the socket shield technique (SST) has been advocated as means to maintain the facial and/or interproximal osseous and gingival architecture. Because SST is a technique-sensitive procedure, various complications related to SST have been reported. This article presents a unique complication after a socket shield procedure and a novel management of the complication. Int J Periodontics Restorative Dent 2023;43:157-165. doi: 10.11607/prd.5426.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Carga Inmediata del Implante Dental/métodos , Alveolo Dental/cirugía , Encía/cirugía , Extracción Dental , Estética Dental , Resultado del Tratamiento
12.
Clin Implant Dent Relat Res ; 25(2): 321-329, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36593583

RESUMEN

OBJECTIVE: The aim of this retrospective study was to investigate the influence of vertical platform discrepancies for splinted and non-splinted adjacent implants on radiographic marginal bone loss (RMBL). METHODS: Data from January 2000 to February 2021 were collected from the electronic charts of 156 patients with 337 implants at the UCSF School of Dentistry. Five different implant restoration categories were evaluated for radiographic evidence of proximal RMBL. Patients with (1) two adjacent single crowns, (2) two adjacent splinted crowns, (3) three-unit bridges supported by two implants, (4) three adjacent single crowns, and (5) three adjacent splinted crowns. Inclusion required baseline radiograph taken at the time of prosthesis delivery or final impression, and follow-up radiographs at least 12 months after restorations have been in function. Measurements assessed included vertical distance between adjacent implant platforms and proximal RMBL around implants. Odds ratios (ORs) and 95% confidence interval (95% CI) of implants with ≥1 mm RMBL between different type of restorations were calculated. RESULTS: In general, prostheses supported by splinted adjacent implants demonstrated a significant association with the presence of ≥1 mm RMBL (OR = 2.55, 95% CI = 1.17-5.17, p = 0.018) when compared to prostheses supported by non-splinted adjacent implants. In addition, prostheses with a vertical platform discrepancy ≥0.5 mm demonstrated a significant association with the presence of ≥1 mm RMBL (OR = 4.30, 95% CI = 1.85 to 10.01, p = 0.007) when compared to prostheses with a vertical platform discrepancy <0.5 mm. When adjacent implants had ≥0.5 mm vertical platform discrepancy, the majority (66.67%) of three splinted adjacent crowns had at least one implant with ≥1 mm RMBL. This was followed by two splinted adjacent crowns (58.97%), three-unit bridge (25.93%), two single adjacent crowns (24.24%), and three single adjacent crowns (18.18%). When adjacent implants had ≥1 mm vertical platform discrepancy, there was an increased percentage of implants with ≥1 mm RMBL. The restorative design associated with the highest percent of implants with bone loss was three splinted adjacent crowns (70%), two splinted adjacent crowns (61.11%), three single adjacent crowns (40%), and three-unit bridge and two single adjacent implants (21.05%). Three splinted adjacent crowns were significantly associated with ≥1 mm RMBL when compared to three-unit bridge (OR 6.56, 95% CI 1.59-27.07). Similarly, two splinted crowns were significantly associated with ≥1 mm RMBL when compared to two single crowns (OR = 2.50, 95% CI = 1.08-5.79). CONCLUSION: Two or three adjacent implants placed with a vertical platform discrepancy, when splinted together, are associated with higherincidence of ≥1 mm RMBL than non-splinted restorations.


Asunto(s)
Implantes Dentales , Humanos , Estudios Retrospectivos , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Coronas , Fracaso de la Restauración Dental
13.
J Esthet Restor Dent ; 35(1): 138-147, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36511151

RESUMEN

OBJECTIVE: A scarf-shaped connective tissue graft can be placed at the facial and proximal aspect of the peri-implant soft tissue zone during immediate implant placement and provisionalization (IIPP) procedures in the esthetic zone to optimize implant esthetics without the need of flap reflection. This retrospective study evaluated soft tissue stability after scarf-connective tissue graft (S-CTG) in conjunction with IIPP procedures in the esthetic zone. MATERIALS AND METHODS: Patients who received IIPP with S-CTG with a minimum 1-year follow-up were evaluated. Mid-facial gingival level (MFGL) change and mid-facial gingival thickness (MFGT) change were measured and compared at the pre-op (T0), IIPP + S-CTG surgery (T1), follow up appointment with MFGT measurement (T2), and latest follow-up appointment (T3). Implant success rate and graft necrosis were also recorded. RESULTS: A total of 22 IIPP and S-CTG procedures in 20 patients were evaluated in the study. After a mean follow-up of 8.2 years (3.9-13.4) (T3), all implants remained osseointegrated (22/22 [100%]), with statistically insignificant mean midfacial gingival level change of -0.19 mm (-1.5 to 0.8). Statistically significant difference in midfacial gingival thickness (MFGT) was noted (2.5 mm [1.8-3.5 mm]) after a mean follow-up time (T2) of 2.3 years (1-8.6) when compared with MFGT at baseline (1.1 mm [0.6-1.3 mm]) (T1). Necrosis of S-CTG during initial healing phase was noted in 9% (2/22) of the sites. CONCLUSIONS: Within the confines of this study, scarf-connective tissue graft at time of immediate implant placement and provisionalization can thicken the gingiva and maintain the gingival level at the critical soft tissue zone. CLINICAL SIGNIFICANCE: Managing the soft tissue zone is as important as that of the hard tissue zone for peri-implant esthetics. Connective tissue graft is one of the methods that can enhance the final esthetic outcomes. This retrospective study has demonstrated that Scarf-CTG technique is an effective treatment modality to maintain soft tissue stability.


Asunto(s)
Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Humanos , Encía/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Tejido Conectivo/trasplante , Maxilar/cirugía , Estética Dental
14.
Clin Implant Dent Relat Res ; 25(4): 640-660, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36533411

RESUMEN

BACKGROUND: Strong evidence suggests the infectious nature of peri-implant diseases occurring in susceptible hosts. Epidemiological reports, though, indicate that peri-implantitis is a site-specific entity. Hence, the significance of local factors that may predispose/precipitate plaque accumulation and the impact of systemic drivers that alter the immune response are relevant in the prevention and management of peri-implant disorders. PURPOSE: The purpose of the present review is to shed light on the significance of local and systemic factors on peri-implant diseases, making special emphasis on the associations with peri-implantitis. METHODS: The biologic plausibility and supporting evidence aiming at providing a concluding remark were explored in the recent scientific literature for local predisposing/precipitating factors and systemic drivers related to peri-implant diseases. RESULTS: Local predisposing factors such as soft tissue characteristics, implant position and prosthetic design proved being strongly associated with the occurrence of peri-implant diseases. Hard tissue characteristics, however, failed to demonstrate having a direct association with peri-implant diseases. Robust data points toward the strong link between residual sub-mucosal cement and peri-implant diseases, while limited data suggests the impact of residual sub-mucosal floss and peri-implantitis. Systemic drivers/habits such as hyperglycemia and smoking showed a strong negative impact on peri-implantitis. However, there is insufficient evidence to claim for any link between metabolic syndrome, atherosclerotic cardiovascular disease, and obesity and peri-implant diseases. CONCLUSION: Local predisposing/precipitating factors and systemic drivers may increase the risk of peri-implant diseases. Therefore, comprehensive anamnesis of the patients, educational/motivational programs and exhaustive prosthetically-driven treatment planning must be fostered aiming at reducing the rate of biological complications in implant dentistry.


Asunto(s)
Implantes Dentales , Periimplantitis , Humanos , Periimplantitis/etiología , Periimplantitis/prevención & control , Implantes Dentales/efectos adversos , Factores Desencadenantes , Susceptibilidad a Enfermedades/complicaciones , Fumar , Factores de Riesgo
15.
J Prosthet Dent ; 130(6): 816-824, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35300850

RESUMEN

STATEMENT OF PROBLEM: Artificial intelligence (AI) models have been developed for periodontal applications, including diagnosing gingivitis and periodontal disease, but their accuracy and maturity of the technology remain unclear. PURPOSE: The purpose of this systematic review was to evaluate the performance of the AI models for detecting dental plaque and diagnosing gingivitis and periodontal disease. MATERIAL AND METHODS: A review was performed in 4 databases: MEDLINE/PubMed, World of Science, Cochrane, and Scopus. A manual search was also conducted. Studies were classified into 4 groups: detecting dental plaque, diagnosis of gingivitis, diagnosis of periodontal disease from intraoral images, and diagnosis of alveolar bone loss from periapical, bitewing, and panoramic radiographs. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. RESULTS: Twenty-four articles were included: 2 studies developed AI models for detecting plaque, resulting in accuracy ranging from 73.6% to 99%; 7 studies assessed the ability to diagnose gingivitis from intraoral photographs reporting an accuracy between 74% and 78.20%; 1 study used fluorescent intraoral images to diagnose gingivitis reporting 67.7% to 73.72% accuracy; 3 studies assessed the ability to diagnose periodontal disease from intraoral photographs with an accuracy between 47% and 81%, and 11 studies evaluated the performance of AI models for detecting alveolar bone loss from radiographic images reporting an accuracy between 73.4% and 99%. CONCLUSIONS: AI models for periodontology applications are still in development but might provide a powerful diagnostic tool.


Asunto(s)
Pérdida de Hueso Alveolar , Placa Dental , Gingivitis , Enfermedades Periodontales , Humanos , Inteligencia Artificial , Gingivitis/diagnóstico
16.
Artículo en Inglés | MEDLINE | ID: mdl-36520126

RESUMEN

It is challenging for implants in the esthetic zone to maintain the facial soft tissue contour and interimplant papillae. To counteract the inevitable hard and soft tissue changes after tooth extraction, the socket shield technique (SST) has been advocated as means to maintain the facial and/or interproximal osseous and gingival architecture. As SST is a technique-sensitive procedure, various complications related to SST have been reported. This article presents a unique complication after a socket shield procedure and a novel management of the complication.

17.
J Oral Implantol ; 48(1): 27-36, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34505160

RESUMEN

The purpose of this study is to compare the exposure rate of 3 different barrier types after a guided-bone regeneration procedure as well as to compare the percentage grafted bone dimensional loss with and without exposed barriers. Patient records from September 2007 to May 2015 were reviewed to identify subjects who had received a bone graft followed by implant placement procedure after the graft had completely healed. The subjects were divided into 3 groups: (1) resorbable barrier, (2) nonresorbable barrier, and (3) titanium-mesh barrier. Incidences of barrier exposure were recorded. Cone-beam computerized tomography images before treatment (T0), right after grafting (T1), and after healing (T2) were used to determine the percentage of grafted bone dimensional loss and am quantitative amount of grafted bone remaining (mm2). Three cross-sectioned areas, at 1-mm apart, of preplanned implant positions at the grafted site were measured using cone-beam computerized tomography to calculate the remaining grafted bone and grafted bone dimensional change. The exposure rate of all guided bone regeneration was 36.9%. The exposure rate of the resorbable barrier (23.3%) was significantly lower than titanium mesh (68.9%) and nonresorbable (72.7%; χ2, P < .001). The results of this study revealed that barrier types have a significant effect on the exposure rate. There was also a significant difference in grafted bone dimensional loss between sites with barrier exposure (58.3%) and sites with no barrier exposure (44.1%) during the healing period (Mann-Whitney U test, P = .008).


Asunto(s)
Aumento de la Cresta Alveolar , Titanio , Aumento de la Cresta Alveolar/métodos , Regeneración Ósea , Trasplante Óseo/métodos , Regeneración Tisular Guiada Periodontal/métodos , Humanos , Estudios Retrospectivos
18.
J Oral Implantol ; 48(3): 187-193, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34091687

RESUMEN

The purpose of this study was to compare heat and sound generated during implant osteotomy when different types of drill were used in artificial bone and bovine bone blocks. A total of 80 implant osteotomies were formed using 4 implant drilling systems: N1 (OsseoShaper) (Nobel), NobelActive (Nobel), V3 (MIS), and BLX (Straumann) in both artificial bone and bovine bone blocks. Thermocouple probes were used to record temperature change at the depths of 5.0 mm and 13.0 mm of each implant osteotomy formed by the final drill. In addition, thermographic images, drilling sound, and drilling time were recorded and evaluated. Statistical analyses were performed at α = 0.05. The mean temperature changes as recorded by thermocouple probes and thermocamera were significantly lower in OsseoShaper than most other drill-bone combinations (P < .05). The mean drilling times and sound generation for OsseoShaper were significantly higher and lower than most other drill-bone combinations (P < .05), respectively. Minimal heat and sound generation can be expected when implant osteotomies are performed using OsseoShaper at a low rotational speed (50 rpm) even without irrigation. However, extended drilling time is required.


Asunto(s)
Implantes Dentales , Calor , Animales , Huesos , Bovinos , Implantación Dental Endoósea , Diseño de Equipo , Osteotomía
19.
Compend Contin Educ Dent ; 42(6): F1-F11, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34077670

RESUMEN

Ten keys for successful esthetic-zone single immediate implants encapsulate in an evidence-based manner the treatment planning and replacement of single hopeless teeth in the maxillary anterior sextant. These include two treatment-planning, five surgical, and three prosthetic keys, which, collectively, aim to minimize soft- and hard-tissue complications for an optimal esthetic implant restoration. The Straightforward, Advanced, and Complex (SAC) classification is designed to aid clinicians in the treatment planning of dental implant cases. As per this classification, cases are stratified by the degree of surgical and restorative risk and complexity for both the surgical and prosthetic phases of treatment. A technique-sensitive and skill-demanding task, the replacement of multiple adjacent teeth in the esthetic zone poses significant challenges for clinicians and is considered a complex SAC procedure surgically and restoratively. This article presents a case report on the replacement of multiple adjacent teeth in the esthetic zone, demonstrating the use of 10 key principles to achieve an optimal esthetic outcome.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Implantación Dental Endoósea , Estética Dental , Humanos , Maxilar/cirugía
20.
J Prosthet Dent ; 125(4): 675-681, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32439126

RESUMEN

STATEMENT OF PROBLEM: Angle-correcting options allow the use of screw-retained implant prostheses in situations where an implant has been placed with a facial inclination. However, manufacturers have different recommended torque values, and it is unclear whether the performance of these designs is equivalent to that of the traditional screw-retained crowns (SRCs) when subjected to cyclic loading forces. PURPOSE: The purpose of this in vitro study was to compare torque differences between conventional straight-line screw access and angulated access SRCs before and after simulated functional loading. MATERIAL AND METHODS: Five groups consisting of 10 SRCs and implants were formed: Nobel Biocare zirconia crowns with 20-degree access channels (NB-20); Dynamic Abutment Solution zirconia crowns (DA-20) with 20-degree access channels; Core3dcentre angle correction zirconia crowns with 20-degree access channels (C3D-20); Nobel Biocare zirconia crowns with 0-degree access channels (NB-0); and gold alloy crowns cast to Nobel Biocare Gold-Adapt abutments (GA-0). Each specimen underwent thermocycling before cyclic loading. A preload torque based on the manufacturer's recommendation was applied to each crown placed on an implant. Reverse torque measurements were obtained for each specimen before cyclic loading. Each implant-abutment assembly was then cyclic loaded at 0 to 100 N at 10 Hz for 1 million cycles. Reverse torque measurements were obtained after cyclic loading and the percentage difference calculated. RESULTS: No significant percentage torque loss differences were observed between the 0-degree and 20-degree SRCs after cyclic loading. No significant differences were seen among the angulated access channel crowns. DA-20 and C3D-20 specimens had significantly higher torque loss compared with the NB-0 group. The C3D-20 group reported the largest percentage torque loss (34.5%) among the angulated access screw channel groups. The GA-0 group reported the largest percentage torque loss of all the groups (35.9%). No crown mobility or other complications were observed in any of the groups after cyclic loading. CONCLUSIONS: Angulated access channel crowns performed comparably with conventional straight-line screw access SRCs with regard to percentage torque values after cyclic loading. Angulated access channel crowns with lower manufacturer recommended torque values had higher percentage torque differences.


Asunto(s)
Pilares Dentales , Implantes Dentales , Tornillos Óseos , Coronas , Diseño de Implante Dental-Pilar , Análisis del Estrés Dental , Torque
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...